IS 3218:2024 Fire Alarm System Assessments Ireland

An independent review of a building's fire alarm arrangements, with findings and recommended actions for management.

Receive: Assessment findings, deficiencies and prioritised recommendations
Site time: Confirmed with your quotation
Programme: Report within 10 working days
Basis: IS 3218
Delivered by: Qualified fire engineer
Review: After relevant changes, recurring faults or concerns about suitability

When an Independent Assessment Helps

Use an independent assessment when management needs to understand whether the alarm arrangements suit the building, or when recurring unwanted alarms, incomplete records or changes in occupancy need investigation. Phoenix STS does not install or maintain alarm systems. This is a visual assessment of the system in operation and of the level of detection provided. It does not include inspection or testing of cabling. The assessment gives management a separate view to discuss with the maintenance contractor and other responsible parties.

What the Assessment Report Covers

  • System category and coverage considered against the building and its use.
  • Review of detection and alarm arrangements and available system documentation.
  • Cause-and-effect arrangements, including door releases and plant shutdowns.
  • Maintenance evidence, recorded faults and unwanted-alarm patterns.
  • A report identifying deficiencies, their significance and recommended actions.

Reviewing the System on Site

The fire engineer examines the available design and maintenance information and reviews the installation on site. The assessment considers how an alarm is raised, how people are warned and how connected systems are intended to respond. Repeated unwanted alarms are considered alongside their recorded causes. Functional testing, access requirements and contractor attendance are agreed in the scope before the visit.

Records Needed for the Assessment

Provide system drawings, the stated system category, commissioning and maintenance certificates, the logbook, fault records and the cause-and-effect schedule where available. Identify alterations to the building or system. Arrange access and a management contact, and flag any activity that cannot be interrupted during the visit.

The Legal and Technical Basis

The Fire Services Acts place duties on the person controlling applicable premises. Regulation 13 of the Safety, Health and Welfare at Work (General Application) Regulations 2007 also addresses fire detection and fire fighting in workplaces. The assessment examines the arrangements against IS 3218; it does not transfer management's duties or replace the contractor's maintenance programme.

Related Support

Request a Quotation

Send the building location, use and size, system details and the concern prompting the assessment. Include relevant fault records and any inspection deadline. Site time and any testing arrangements are confirmed with the quotation. Allow up to 10 working days for the report to be issued. We reply within five working days.

Before Commissioning the Work

About Phoenix STS

Established in 2000. Phoenix STS is based in Longford and works at clients' premises throughout Ireland.

Phoenix STS Ltd holds Dual Accreditation with the Professional Development Consortium as a Dual Provider of Training Excellence. Provider references: PDCD1104 / 22657. Provider listing.